Show Posts
|
Pages: [1] 2 »
|
1
|
Alternate cryptocurrencies / Mining (Altcoins) / Re: miniZ fast Equihash miner 144,5 150,5,3 125,4 192,7 210,9 150,5 BeamHashIII 96,5
|
on: December 12, 2020, 09:16:22 PM
|
* 192,7 major improvements: ~2-11% depending on GPU. Turing GPUs, and 1050 Ti, have the largest improvements. * Reduced invalid shares on 192,7. * Added 2GB kernel for 192,7 (Linux/Windows7). * Added 2GB kernel for 144,5s (beamhash3) (Windows7).
Amazing!!! Not just BEAM but also ZCL! You are so cool! Let's see fee from my 22*1050 soon=)
|
|
|
0.18.2 * (ethash, kawpow, progpow) Performance improvements on Windows for some configurations up to 3% Got cuda exception in [trexInitializerM, 194], unspecified launch failure errors for all cards after upgrading from 16.2 to 18.2 Disabling core and memory overclock didn't help. Asus Phoenix 1063, Win7 SP1, Driver 451.67, core voltage 700mv (732mv also didn't work). start /b /w /HIGH t-rex --devices 0,1,2,3,4 -a kawpow --mt 3 -o stratum+tcp://rvn.2miners.com:6060 -u wallet.worker -p x --log-path logs\t-rex.log --cpu-priority 5 --temperature-limit 80 --temperature-start 60 --temperature-color 64,72 --exit-on-cuda-error Removing -mt also din't help 16.2 works perfectly with -lockVoltagePoint:0,700000 -setBaseClockOffset:0,0,152 -setMemoryClockOffset:0,0,500
|
|
|
3
|
Alternate cryptocurrencies / Mining (Altcoins) / Re: miniZ fast Equihash miner 144,5 150,5,3 125,4 192,7 210,9 150,5 BeamHashIII 96,5
|
on: October 05, 2020, 04:58:09 PM
|
Is it possible to mine BeamHash III on GTX 1050 2GB under Windows 7? ... So sad, what's just 17 mb lacks. Whether there is a possibility to reduce Win7 GPU memory usage?
We'll see if we can shrink it a little. However, keep in mind that this will decrease performance. Any news?
|
|
|
4
|
Alternate cryptocurrencies / Mining (Altcoins) / Re: miniZ fast Equihash miner 144,5 150,5,3 125,4 192,7 210,9 150,5 BeamHashIII 96,5
|
on: September 23, 2020, 08:42:13 PM
|
Is it possible to mine BeamHash III on GTX 1050 2GB under Windows 7? I get an error: miniZ requires at least 1930MB to run, but only has 1913MB
So sad, what's just 17 mb lacks. Whether there is a possibility to reduce Win7 GPU memory usage? Default theme, no wallpaper, 1024 resolution already installed. Maybe downgrade to some old nvidia drivers?
Or the only possibility is to migrate to Linux?
|
|
|
Sup guys. Zel made ~5x in last couple of weeks in BTC. And almost reached the last year's ATH in USD. What could be the reason of this rise? Looks kinda miraculous.
Binance CEO announced partnership with ZEL.
|
|
|
Guys, what is your hashrate on c31 using 1080ti on Windows? I have about 0.75-0.87 per card (but 7.12 on c29)
Win7, 1080ti Asus Strix, 416.94 drivers 949mv locked, power limit 100% (working at about 80% average), core +220 (working at about 1923 mhz) memory +400 at P0 (working at 5899 mhz) + Pill
|
|
|
Guys, what is your hashrate on c31 using 1080ti on Windows?
|
|
|
Gminer v1.31 gives about 11 sol per 1063 card Win7, 1063 MSI + MSI Gaming, 416.94 drivers 824mv locked, power limit 100% (working at about 66% for regular MSI and about 55% for MSI Gaming) core +170-205 (working at about 1708-1759 mhz) memory +500 at P0 (working at 4498 mhz)
|
|
|
v14.3.0 crashing at mining BEAM on 1063 with [INFO] [2019-02-11T13:37:06+02:00] CUDA error DRIVER: '2' in func 'bminer::equih ash::legacy::Equihash1505SolverCuda::Initialize' line 59 [FATA] [2019-02-11T13:37:06+02:00] Fatal cuda error in GPU 0. Terminate soon... Gminer works fine with about 11 sol per card Win7, 1063 MSI + MSI Gaming, 416.94 drivers 824mv locked, power limit 100%, core +170-205 (working at about 1708-1759 mhz) memory +500 at P0 (working at 4498 mhz)
|
|
|
Win7, 1080ti Asus Strix, 416.94 drivers Only 0.87 G/s per card on c31, but 7.12 on c29.
949mv locked, power limit 120% (working at about 80% average), core +220 (working at about 1923 mhz) memory +400 at P0 (working at 5899 mhz) + Pill
|
|
|
Blockchain is still alive, 168 masternodes online. There is addnode list if anybody needs it: addnode 95.171.6.104 addnode 80.209.228.66 addnode 45.32.25.156 addnode 5.39.4.124 addnode 45.63.68.24 addnode 87.103.215.89 addnode 91.227.18.79 addnode 91.227.18.86 addnode 162.218.209.55 addnode 162.218.209.54 addnode 134.249.150.151 addnode 84.227.192.235 addnode 46.14.174.209 addnode 162.218.209.53 addnode 178.79.139.201 addnode 162.218.209.52 addnode 144.202.72.84 addnode 149.56.140.3 addnode 162.218.209.51 addnode 217.175.0.72 addnode 149.6.195.40 addnode 80.208.224.55 addnode 149.56.128.142 addnode 93.126.126.51 addnode 45.63.8.91 addnode 94.130.184.67 addnode 74.208.94.233 addnode 185.159.131.102 addnode 45.77.68.41 addnode 80.211.223.182 addnode 162.218.209.50 addnode 195.209.103.4 addnode 45.63.71.141 addnode 80.211.144.219 addnode 94.177.215.52 addnode 108.61.126.237 addnode 207.246.124.75 addnode 185.244.217.226 addnode 74.208.200.228 addnode 54.37.73.39 addnode 45.32.120.169 addnode 212.8.244.4 addnode 139.99.107.2 addnode 162.218.209.36 addnode 162.218.209.49 addnode 37.17.172.188 addnode 217.18.160.143 addnode 188.166.213.213 addnode 108.61.87.241 addnode 92.242.3.82 addnode 159.65.102.241 addnode 185.197.75.202 addnode 31.14.133.47 addnode 173.249.34.54 addnode 162.218.209.35 addnode 212.237.25.226 addnode 5.129.88.119 addnode 220.89.7.193 addnode 45.76.144.131 addnode 162.218.209.34 addnode 207.112.18.86 addnode 178.238.224.253 addnode 90.84.229.42 addnode 89.35.73.179 addnode 162.218.209.33 addnode 162.218.209.32 addnode 162.218.209.223 addnode 162.218.209.228 addnode 162.218.209.229 addnode 162.218.209.230 addnode 162.218.209.231 addnode 162.218.209.232 addnode 162.218.209.233 addnode 162.218.209.234 addnode 162.218.209.235 addnode 162.218.209.236 addnode 104.168.127.11 addnode 198.96.91.37 addnode 91.202.25.26 addnode 66.154.105.101 addnode 198.13.60.150 addnode 45.32.16.130 addnode 209.250.251.112 addnode 66.154.105.110 addnode 66.154.105.167 addnode 66.154.105.235 addnode 204.44.95.89 addnode 45.77.191.191 addnode 204.44.95.88 addnode 204.44.95.87 addnode 80.242.70.63 addnode 185.239.237.134 addnode 185.239.239.60 addnode 104.238.162.100 addnode 45.32.164.167 addnode 207.148.8.115 addnode 51.15.232.206 addnode 94.177.160.161 addnode 62.183.22.138 addnode 45.63.68.102 addnode 144.202.21.100 addnode 140.82.49.46 addnode 207.246.73.92 addnode 207.246.77.112 addnode 45.77.209.38 addnode 204.44.95.71 addnode 204.44.95.70 addnode 204.44.95.69 addnode 204.44.95.194 addnode 204.44.95.195 addnode 204.44.95.196 addnode 144.202.99.94 addnode 45.76.2.74 addnode 140.82.5.153 addnode 96.42.30.122 addnode 204.44.95.198 addnode 173.249.9.82 addnode 109.87.42.90 addnode 204.44.95.199 addnode 87.103.214.89 addnode 207.148.13.103 addnode 45.63.105.183 addnode 45.77.123.118 addnode 204.44.95.211 addnode 95.171.6.43 addnode 185.239.236.79 addnode 204.44.95.23 addnode 204.44.95.33 addnode 204.44.95.42 addnode 69.12.94.9 addnode 104.223.96.239 addnode 104.223.96.207 addnode 104.223.96.206 addnode 104.223.96.205 addnode 178.151.212.160 addnode 104.223.96.204 addnode 104.223.96.203 addnode 104.223.96.202 addnode 147.135.178.0 addnode 145.239.109.60 addnode 217.182.36.218 addnode 178.32.52.45 addnode 54.36.30.124 addnode 87.98.235.194 addnode 188.165.10.239 addnode 176.31.214.147 addnode 164.132.88.93 addnode 54.36.214.51 addnode 147.135.201.197 addnode 46.105.62.116 addnode 91.134.232.237 addnode 54.36.5.66 addnode 213.32.11.59 addnode 54.38.165.182 addnode 54.36.214.50 addnode 178.32.196.247 addnode 51.255.140.176 addnode 91.134.244.128 addnode 5.39.113.103 addnode 79.137.56.119 addnode 94.23.150.46 addnode 178.33.116.134 addnode 147.135.178.2 addnode 147.135.184.160 addnode 54.37.175.42 addnode 79.137.50.67 addnode 104.223.96.201 addnode 104.223.96.200
|
|
|
47-48°C на эфире - отличный результат для такой жаркой погоды. Это у вас с боковыми продувными вентиляторами на самом риге или без них?
С боковыми 120-ками вдоль всей длины рига (6 вентиляторов). Стоят впритык друг к другу, т.е. дуют и на карты и между ними. 1200 оборотов, самые обычные, самые дешёвые вентиляторы на молекс с доп. разьемом дня подключения следующего молекса. Одни только боковые корпусные вентиляторы дают около минус 6-7 градусов на открытом риге. Ставить на вдув со стороны крепления карты. Офисные вентиляторы что прокачивают воздух через балкон дают ещё минус 2-4 градуса на эфире и 6-8 на неоскрипте.
|
|
|
Отличный результат, у меня strixы но выше 50 Mh/s не хожу, раз в пару дней ошибка появляется и зависание, если разгоняю сильнее, при этом температура карты в районе 60-62 гр.
Strix'ы, 55.5 mh, стабильно по неделе, дольше не держал, тк всё время повышаю частоту/уменьшаю потребление и тестирую. 0.8mv (залочено курвой) +190 core (падает меньше, до ~0.781 тк пережат power) +870 memory = P0 (+500 memory) +370, итого память +870 73% power частота прыгает ~1480-1645 тк нехватает power 55.5 mh с карты 690W с рига 3*1080ti Температура карт 47-48°C, балкон, солнечная сторона, но с закленными окнами и боковыми корпусными вентиляторами на риге. Плюс по офисному вентилятору на вдув с одного окна и выдув с другого (2*35W).
|
|
|
Тоже думала на о балконе, но у меня солнечная сторона, жалюзи все завесить не вариант, все равно получалось, как в парилке. Пришлось приспособить отдельную комнату. И двери держать закрытыми ну и охлаждение нормальное. Стекла на балконе заклеиваете обычной дешевой пленкой от солнца, но в 2-3 слоя. А сверху жалюзи (пластиковые! Не железные). Температура падает очень сильно. А если ещё боковые вентиляторы корпусные поставить на фермы и по офисному вентилятору на вдув и выдув с разных окон балкона, то будет ещё холодней. У меня карты 47-48°C на эфире при +30-35 на улице на солнечном балконе.
|
|
|
hsrminer freezes if UAC is disabled on Win7x64 Pro. Checked on 2 different rigs: gtx1063 and gtx1080ti. Nvidia driver version doesn't matter.
|
|
|
Blockchain and Explorer are still alive, that's good. Anyone have Discord link?
|
|
|
Why do Ukrainians have their own board, they can communicate in a Russian board. If we will write in Ukrainian inside Russian sub-forum, than these topics will be absolutely unclear for people from Russian sub-forum.
|
|
|
Сколько сейчас нода стоит монет? Пока копал 1000, смотрю уже видимо 5000+ надо. Придется избавляться видимо от них(
Сейчас нода стоит 3000 TUN. После 100к блока должно было пройти голосование по увеличение стоимости для новых нод (уже запущенные остаются как есть), но пока его не было.
|
|
|
What are the difference between "--max-temp=N" and "--tlimit=N"? Can they work together?
|
|
|
|