Error 30 is that the connection to your pool as been interrupt. Maybe a problem with your address. Most of the time for me this error appear with i start a T3h for the first time but it goes away after like 10 min of running.
I do have all the tool that I need. I run a diag with a control board and a power supply. It tell me where the signal stop. After this, I have an oscilloscope and look at my signals and I can see SDO/SDI/CLK/CS and from that I know where the problem is. Maybe its too deep to ask something like that here.
I don't replace all the chips. Just the chips that I need to.
I change the chip from the hash-board and yes they are replaceable. They're 114 chips.. so I run a diag to see where the problem is. And with this one in particular, it say the the SPI is failing somewhere between those chips. I tough it was the UT3 but it isn't.
2) I cant see the defective board on Innoscilicon cause the board shut down. Inno monitor say error 24 (communication error from chip) and the board #2 is not working.
I have some problems with some of my T3H miners. I got the error code 24 witch mean the communication of some chips doesn't work well. So I get the defective board out and when I run the diag, I see that there's a problem around the chip UT3 but even if I change it, the problem still there.
Is anyone here do repair their board and can help me with that.
Always doing that but one thing I was doing before was adding tin on my chip before soldering it to the board. Now i just dont and it help a lot with that kind of problems.
How are you trying to change the chip? What tools/heat settings/flux/solder masks?
Well I take the defective board out of the miner, take all the heat sink off the board, heat both side of the board at 300 degree and then i can change the chip i need to. I dont know if this forum will be helpful with that kind of problems.